BUYGLASS.CO · SPECIFICATION HELP

Fire-rated glass

Find a useful starting point for your fire-glass enquiry. Compare candidate systems by application, framing, performance and size, then discuss the complete specification with your project specialist.

These reference records need current certificate review. BS 476 integrity / insulation minutes do not automatically establish EN 13501 E/EW/EI classifications.

Glass selector

Your project

These filters screen recorded evidence. Your project specialist must verify the complete frame, seals, fixings, aperture and fire exposure. A material name or area alone cannot approve a system.

Optional advanced details

32 of 32 models have candidate records. Sorted by indicative price; verification remains required.

Candidate systems

Pyroguard Clear 11mm

Pyroguard · CF257 · 7 candidate records

Reference rate £270.18/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 18, 48, 57, 58 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 6, 7, 8, 9, 10, 11, 12, 13, 38, 42, 43 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 21, 22, 23, 24, 27, 28, 29, 30, 31, 32, 33, 34, 37, 50, 55, 56 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 25, 26, 41, 51, 52, 53, 54 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 41 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 14, 15, 16, 44 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 17, 46 ↗ · extract not independently rechecked

Pyroguard Clear 7mm

Pyroguard · CF257 · 7 candidate records

Reference rate £270.18/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber / Steel · IGU / Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 21, 22, 23, 24, 27, 28, 29, 30, 31, 32, 33, 34, 37, 38, 42, 43, 44, 46, 48, 50, 55, 56, 57, 58 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 14, 15, 16, 44 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 19 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 17, 46 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 21, 22, 23, 24, 27, 28, 29, 30, 31, 32, 33, 34, 37, 50, 55, 56 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 25, 26, 51, 52, 53, 54 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF257 source pages 6, 7, 8, 9, 10, 11, 12, 13, 38, 42, 43 ↗ · extract not independently rechecked

AGC Flatglass Pyrobelite 10

AGC Flatglass · CF377 · 1 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 13, 14, 18, 26 ↗ · extract not independently rechecked

AGC Flatglass Pyrobelite 12

AGC Flatglass · CF377 · 4 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 16, 19, 24, 25, 33 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 34, 52, 64 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 32 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 12, 30, 31 ↗ · extract not independently rechecked

AGC Flatglass Pyrobelite 7 & 9EG (IGUs)

AGC Flatglass · CF377 · 2 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 13, 14, 18 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 16, 19 ↗ · extract not independently rechecked

AGC Flatglass Pyrobelite 7 & 9EG

AGC Flatglass · CF377 · 3 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 16, 19 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 7, 8 ↗ · extract not independently rechecked

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 13, 14, 18 ↗ · extract not independently rechecked

Pilkington pyrodur 30-105, 7mm

Pilkington · CF328 · 1 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber · IGU / Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 14, 15 ↗ · extract not independently rechecked

Pilkington pyrodur 30-203, 11mm

Pilkington · CF328 · 1 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 20 ↗ · extract not independently rechecked

Pilkington pyrodur 60-20, 13mm

Pilkington · CF328 · 1 candidate records

Reference rate £297.00/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Steel / Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 25, 27, 28 ↗ · extract not independently rechecked

Pilkington pyrodur 60-10, 10MM

Pilkington · CF328 · 1 candidate records

Reference rate £549.78/m²Full details →

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 23, 24 ↗ · extract not independently rechecked

Pyroguard 15mm

Pyroguard · CF437 · 9 candidate records

Reference rate £627.00/m²Full details →

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 26, 32, 34 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 23, 33 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 31 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 22 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 15, 16, 17, 59 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 54 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 21 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 24, 25, 27 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 57, 58 ↗ · extract not independently rechecked

Pilkington pyrostop 30-10, 15MM

Pilkington · CF328 · 1 candidate records

Reference rate £657.80/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Aluminium · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 6, 9, 11, 13, 14 ↗ · extract not independently rechecked

Pilkington pyrostop 30-103, 14mm

Pilkington · CF328 · 5 candidate records

Reference rate £657.80/m²Full details →

Integrity 30 min / insulation 30 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · See certificate

54 mm timber doorset; ceramic tape 15 × 3 mm compressed to 2 mm; beads and fixings per CF328 page 30

Door aperture W × H as stated; doorset evidence required · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 30 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 30 min / insulation 30 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · See certificate

Softwood frame 33 × 70 mm, density at least 450 kg/m³; ceramic tape and beads per CF328 page 31

Portrait; vertical within ±10° · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 31 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 30 min / insulation 30 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · See certificate

Softwood frame 33 × 70 mm, density at least 450 kg/m³; ceramic tape and beads per CF328 page 31

Landscape; vertical within ±10° · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 31 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 30 min / insulation 30 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · See certificate

Steel screen with 15 × 2 mm Fibrefrax glazing tape; supporting frame evidence required, CF328 page 32

Portrait; vertical within ±10° · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 32 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 30 min / insulation 30 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · See certificate

Steel screen with 15 × 2 mm Fibrefrax glazing tape; supporting frame evidence required, CF328 page 32

Landscape; vertical within ±10° · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 32 ↗ · revision 2024-10-22; checked 2026-10-02

Pilkington pyrostop 30-20, 18mm

Pilkington · CF328 · 1 candidate records

Reference rate £657.80/m²Full details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Aluminium · Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF328 source pages 16, 19 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 16 & 16EG (DGUs)

AGC Flatglass · CF377 · 1 candidate records

Reference rate £679.14/m²Full details →

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 36, 37, 38 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 16 & 16EG (IGUs)

AGC Flatglass · CF377 · 2 candidate records

Reference rate £679.14/m²Full details →

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 49, 54 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 40, 48 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 16 & 16EG (Timber Screens)

AGC Flatglass · CF377 · 1 candidate records

Reference rate £679.14/m²Full details →

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 40, 48 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 16 & 16EG

AGC Flatglass · CF377 · 4 candidate records

Reference rate £679.14/m²Full details →

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 49, 54 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 35 ↗ · extract not independently rechecked

Integrity 30 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 36, 37, 38 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 39, 41 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 16

AGC Flatglass · CF377 · 2 candidate records

Reference rate £679.14/m²Full details →

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 34, 52, 64 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 53, 63 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 17N

AGC Flatglass · CF377 · 4 candidate records

Reference rate £679.14/m²Full details →

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 39, 41, 62 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 53, 63 ↗ · extract not independently rechecked

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Aluminium · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 65 ↗ · extract not independently rechecked

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 34, 52, 64 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 30, 30EG & 30DGU

AGC Flatglass · CF377 · 1 candidate records

Reference rate £679.14/m²Full details →

Integrity 90 min / insulation 90 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 86, 87, 88 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 53, 53N EG

AGC Flatglass · CF377 · 1 candidate records

Reference rate £679.14/m²Full details →

Integrity 120 min / insulation 120 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 89 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel Clearvision 16

AGC Flatglass · CF377 · 1 candidate records

Reference rate £679.14/m²Full details →

Integrity 60 min / insulation 30 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 53, 63 ↗ · extract not independently rechecked

Pyroguard 23mm

Pyroguard · CF437 · 6 candidate records

Reference rate £1089.00/m²Full details →

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 47, 48, 50 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 41, 46 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 49, 55, 56 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 45, 61 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 42, 43, 44 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 19 Feb 2031; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF437 source pages 35, 36, 37, 38, 39, 40 ↗ · extract not independently rechecked

Pilkington pyrostop 60-101, 23mm

Pilkington · CF328 · 3 candidate records

Reference rate £1111.00/m²Full details →

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · See certificate

Hardwood frame 95 × 45 mm, density at least 640 kg/m³; 20 × 2 mm Interdens; beads/fixings per CF328 page 49

Vertical screen, within ±10°; preserve stated W × H orientation · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 49 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · See certificate

Previously tested or Certifire approved insulated steel framing; 15 × 2 mm Fibrefrax; aperture evidence required, CF328 page 50

Vertical screen, within ±10°; preserve stated W × H orientation · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 50 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · See certificate

Fully insulated steel doorset with aperture evidence; 12 × 6 mm Fibrefrax, CF328 page 51

Door aperture W × H as stated; fully insulated doorset evidence required · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 51 ↗ · revision 2024-10-22; checked 2026-10-02

Pilkington pyrostop 60-201, 27mm

Pilkington · CF328 · 3 candidate records

Reference rate £1111.00/m²Full details →

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · See certificate

Hardwood frame 95 × 45 mm, density at least 640 kg/m³; 20 × 2 mm Interdens; beads/fixings per CF328 page 49

Vertical screen, within ±10°; preserve stated W × H orientation · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 49 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · See certificate

Previously tested or Certifire approved insulated steel framing; 15 × 2 mm Fibrefrax; aperture evidence required, CF328 page 50

Vertical screen, within ±10°; preserve stated W × H orientation · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 50 ↗ · revision 2024-10-22; checked 2026-10-02

Integrity 60 min / insulation 60 min

BS 476 Part 22:1987 · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · See certificate

Fully insulated steel doorset with aperture evidence; 12 × 6 mm Fibrefrax, CF328 page 51

Door aperture W × H as stated; fully insulated doorset evidence required · Check complete-system exposure restrictions; glass alone has no general direction restriction (page 4).

Within stated validity to 22 Oct 2029; issuer status still requires checking

Conditions and outstanding checks
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.
  • Qualified BS 476 integrity/insulation minutes; not an EN 13501 EI classification.
  • Tabulated pairs are conservative screening bounds; no interpolation or rotation is performed.
  • Complete frame, seal and installation evidence must be checked by the project specialist.

CF328 source pages 51 ↗ · revision 2024-10-22; checked 2026-10-02

AGC Flatglass Pyrobel 25-25DGU

AGC Flatglass · CF377 · 1 candidate records

Reference rate £1155.00/m²Full details →

Integrity 120 min / insulation 120 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 89, 91, 92, 93, 96 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 25 & 25EG (IGUs)

AGC Flatglass · CF377 · 3 candidate records

Reference rate £1155.00/m²Full details →

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 72, 73 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 70, 71, 75 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · IGU · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 67, 68, 69 ↗ · extract not independently rechecked

AGC Flatglass Pyrobel 25 & 25EG

AGC Flatglass · CF377 · 4 candidate records

Reference rate £1155.00/m²Full details →

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 72, 73 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Steel · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 70, 71, 75 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 66 ↗ · extract not independently rechecked

Integrity 60 min / insulation 60 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Screen · Timber · Single · Internal or External

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Within stated validity to 20 Jun 2029; issuer status still requires checking

Conditions and outstanding checks
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF377 source pages 67, 68, 69 ↗ · extract not independently rechecked

Pyroguard EW30/11-2

Pyroguard · CF5818 · 1 candidate records

Price on requestFull details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber / Steel · IGU · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Expired 8 Oct 2026 — renewed evidence required

Conditions and outstanding checks
  • Expired 8 Oct 2026 — renewed evidence required
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF5818 source pages 14, 36, 37, 58, 59, 63, 66, 68 ↗ · extract not independently rechecked

Pyroguard EW30/7-1

Pyroguard · CF5818 · 1 candidate records

Price on requestFull details →

Integrity 30 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Timber / Steel · IGU / Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Expired 8 Oct 2026 — renewed evidence required

Conditions and outstanding checks
  • Expired 8 Oct 2026 — renewed evidence required
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF5818 source pages 7, 8, 9, 10, 11, 12, 13, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 56, 57, 62 ↗ · extract not independently rechecked

Pyroguard EW60/11-2

Pyroguard · CF5818 · 1 candidate records

Price on requestFull details →

Integrity 60 min / insulation 0 min

Test regime requires verification · no automatic E/EW/EI equivalence

Application and assembly

Door / Screen · Steel / Timber · IGU / Single · Internal

Exact construction requires certificate review

Orientation unverified · Fire direction unverified

Expired 8 Oct 2026 — renewed evidence required

Conditions and outstanding checks
  • Expired 8 Oct 2026 — renewed evidence required
  • Extracted technical record has not been checked against the current system certificate.
  • Internal/external suitability must be confirmed.
  • Exact framing/glazing system has not been supplied.
  • Orientation and fire exposure direction require confirmation.
  • Enter width and height; area alone cannot verify aperture limits.
  • Project specialist must check all frame, seal, fixing, supporting assembly and exposure conditions.

CF5818 source pages 16, 17, 18, 19, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 60, 61, 64, 67, 69 ↗ · extract not independently rechecked

E

Integrity for the classified duration. It does not establish radiation control or insulation.

The complete system and classification report determine E performance.

EW

Integrity plus a radiation limit for the classified duration. EW is distinct from E and from EI.

Check radiation performance in the system classification report.

EI

Integrity plus insulation for the classified duration. A BS 476 integrity/insulation pair alone is not an EN 13501 EI classification.

Specify class and minutes from the project fire strategy.

INT / EXT / EG

Manufacturer location/exposure terminology, separate from fire-resistance class. Confirm the specific glass, system and installation conditions.

Internal/external suitability cannot be inferred from the letters E, EW or EI.

Fire glass by manufacturer

Explore the recorded ranges. Each installation needs current evidence for the complete glazing system.

Source certificates

Recorded Warringtonfire Certifire references. Check the issuer’s current status, revision and all system conditions before specification.

CertificateScope / holderRevised / reissuedStated validitySource
CF437Pyroguard EI (INT/EXT)
Pyroguard UK Ltd
10 Feb 2026Within stated validity to 19 Feb 2031; issuer status still requires checkingPDF ↗
CF257Pyroguard EW (verify radiation classification)
Pyroguard UK Ltd
16 Dec 2025Within stated validity to 19 Feb 2031; issuer status still requires checkingPDF ↗
CF377AGC Pyrobel / Pyrobelite (EG = external)
AGC Glass UK Ltd
6 Aug 2024Within stated validity to 20 Jun 2029; issuer status still requires checkingPDF ↗
CF328Pilkington Pyrodur / Pyrostop
Pilkington UK Ltd
22 Oct 2024Within stated validity to 22 Oct 2029; issuer status still requires checkingPDF ↗
CF5818Pyroguard Advance 2-EW/2-FD/2-EI
Pyroguard UK Ltd
16 Sep 2025 (rev)Expired 8 Oct 2026 — renewed evidence requiredPDF ↗