How glass unit U-values are calculated?
U-values, also known as thermal transmittance values, measure the rate of heat transfer through a building element, such as an Insulated Glass Unit (IGU). The U-value represents the amount of heat that passes through one square meter (m²) of the element when there is a temperature difference of one degree Celsius (°C) between the interior and exterior environments. Lower U-values indicate better insulation and energy efficiency.
To calculate the U-value of a glass unit, you need to consider three main factors:
- Thermal resistance of the glass panes (Rg): The thermal resistance of each glass pane depends on its thickness and thermal conductivity. Generally, thicker glass panes have higher thermal resistance.
- Thermal resistance of the spacer bars (Rs): Spacer bars separate the glass panes in an IGU and maintain the gas-filled cavity between them. Different spacer materials have different thermal resistances, with some materials like low-conductivity warm-edge spacers offering better insulation than conventional aluminum spacers.
- Thermal resistance of the cavity between the glass panes (Rc): The cavity between the glass panes in an IGU can be filled with air, vacuum, or inert gas (such as argon or krypton). Inert gases and vacuum offer better thermal insulation than air, as they have lower thermal conductivity.
To calculate the overall U-value of an IGU, you first need to determine the thermal resistance (R-value) of each component:
- Calculate the R-value of each glass pane by dividing its thickness (in meters) by its thermal conductivity (W/m·K).
- Calculate the R-value of the spacer bars using their thickness and thermal conductivity.
- Calculate the R-value of the cavity by dividing its thickness by the thermal conductivity of the gas or vacuum filling the cavity.
Next, add the R-values of all the components (Rg, Rs, and Rc) to obtain the total thermal resistance (Rt) of the IGU:
Rt = Rg1 + Rs + Rg2 + Rc
Finally, calculate the U-value by taking the reciprocal of the total thermal resistance (Rt):
U-value = 1 / Rt
The result is expressed in watts per square meter per degree Celsius (W/m²·K). Note that this is a simplified approach and assumes a uniform temperature distribution across the glass unit. In practice, more advanced methods and software tools are often used to calculate U-values accurately, taking into account factors like radiation, convection, and edge effects.
Shop Double Glazing Units
STANDARD SAFETY REPLACEMENT UNITS
-
Double Glazing
Buy Double Glazing Unit | 1st:4mm Clear Toughened | 2nd:4mm Clear Toughened | Warm or Alu Spacer | Safety Glass
Original price was: £98.65.£79.01Current price is: £79.01. inc VAT sq m
A RATED GLASS UNITS Calculator
-
Double Glazing
Buy Double Glazing Unit | 1st:4mm HP Low E Toughened | 2nd:4mm Clear Toughened | Warm or Alu Spacer | Safety Glass| Energy Efficient Glass
Original price was: £184.03.£92.02Current price is: £92.02. inc VAT sq m
Shopfront Glazing A Rated
-
Double Glazing
Buy DGU | 1st:4mm HP Low E Toughened | 2nd:6.8mm Clear Laminate | Warm or Alu Spacer | Safety Glass| Energy Efficient Glass
Original price was: £221.81.£138.00Current price is: £138.00. inc VAT sq m
LEAVE A COMMENT